PRIORITY: TEST_TYPE: APPROVED_QE: INPUT: Overall Pre-condition: 1. Printer must be upgraded with the latest build. 2. Connect MFD to Teraterm/putty and login as root. FILES: TESTCASE_HEADLINE: NC resynchronization TESTCASE_VERSION: AUTOMATABLE_NOTAUTOMATABLE: FEATURE: APPROVE_SE: SPEC_VERSION: 1.0027. MFF: TESTCASE_PLATFORM: SPEC: HISTORY: DATA_LOGIC: CDATE: 1578307112 TESTCASE_APPROVALS: TESTCASE_STATE: OUTPUT: 03-332 fault code will be generated by CCM if the device is not resynchronized within 11 minutes and device will automatically attempt NC resynchronization after 11 minutes.. FILEDESC: PROCESS: RESOURCE_HW: TC_WEIGHTAGE: APPROVED_SPAR: MDATE: 1578307112 SKILL_SET: TESTCASE_SOURCE: TEST_CASE_TYPE: APPROVE_QE: APPROVED_SE: PLANNEDTIMESTAFF: ATM_OWNER: AUTHOR: w63LLLNF IMPLEMENTED: LOE: ASSOCIATED_TESTCASES: ATM_REQLINK: TRAINING: GROUP: MUSER: w63LLLNF SUB_FEATURE: SPEC_TAG: After power up, if the NC doesn’t resynchronize within 5 minutes from a synchronization loss or during normal run ,if the NC doesn’t resynchronize within 11 minutes from synchronization loss: CCS declares a 03-332 fault but continue to attempt re-synchronisation. PROCEDURE: 1. Perform the NC Crash (stop_nc) via back channel. 2. Let the device undisturbed for 11 minutes. RESOURCE_CONSUMEABLES: ATM_LOCKED: 0 APPROVE_SPAR: TESTCASE_PRODUCT: QA_TEAM: FILENAME: ATM_ID: AFA1578E-3070-11EA-B581-4589B48AF888 ATM_MCOMMENTS: Copied from "PUQE-CFT_Atlantis_2.0-D5.1/FS_32.001_Crash_and_Power_Recovery/39076 NC resynchronization". RESOURCE_MEDIA: ATM_REQCOUNT: 0