ATM_ID: 180C3A3A-F3AC-11E8-947E-1518CDD1F86B ID: PUQE-CFT_Atlantis_2.0M/Kiska/FS_32.001_Crash_and_Power_Recovery/38013 TESTCASE_HEADLINE: [32.001.026] (FT-22956)[D4.0 - *] In the event that five successive reboots are detected, the system shall be considered to be in a state of “rolling reboot”. Instead of rebooting a sixth time, the system shall: GROUP: FEATURE: SUB_FEATURE: PROCEDURE: 1. Machine back channel: Run below commands- 2. Enter: bu etc/rc.d/init.d/rollingRebootMonitor etc/rc.d/init.d/rollingRebootMonitor etc/rc.d/init.d/rollingRebootMonitor etc/rc.d/init.d/rollingRebootMonitor eu reboot 3. Observe machine behavior. OUTPUT: Machine should not go for reboot after 5 reboots. PROCESS: PRIORITY: TEST_TYPE: LOE: RESOURCE_HW: RESOURCE_CONSUMEABLES: RESOURCE_MEDIA: SKILL_SET: TEST_CASE_TYPE: TESTCASE_SOURCE: SPEC: [32.001.026] (FT-22956)[D4.0 - *] SPEC_VERSION: 1.0027. SPEC_TAG: [32.001.026] (FT-22956)[D4.0 - *] In the event that five successive reboots are detected, the system shall be considered to be in a state of “rolling reboot”. Instead of rebooting a sixth time, the system shall: ATM_OWNER: ASSOCIATED_TESTCASES: TRAINING: TESTCASE_VERSION: TESTCASE_STATE: TESTCASE_PLATFORM: TESTCASE_PRODUCT: TESTCASE_APPROVALS: CDATE: 1543478109 MDATE: 1543478109 MUSER: w4y5hbch AUTHOR: w4y5hbch ATM_MCOMMENTS: Imported from spreadsheet HISTORY: ATM_LOCKED: ATM_REQLINK: 2AEA1B3E-F39F-11E8-AF0B-4C06CDD1F86B ATM_REQCOUNT: 1 FILENAME: FILEDESC: FILES: QA_TEAM: APPROVE_QE: APPROVED_QE: APPROVE_SE: APPROVED_SE: APPROVE_SPAR: APPROVED_SPAR: MFF: PLANNEDTIMESTAFF: IMPLEMENTED: DATA_LOGIC: AUTOMATABLE_NOTAUTOMATABLE: TC_WEIGHTAGE: